Where do old valves go? Here at Custom Valve we have our own way of “Re-purposing” those old valves. Our GREEN-LINE Certified reconditioned valves
are valves that have been carefully reconditioned and meet all the same standards as new valves at half the price.
Our GREEN-LINE valves include Gate valves, Ball
Valves, Globe Valves, Control Valves and include manufactures such as Fisher, Copes, Masonelian, Valtek and Crane. All can be customized by us to meet the needs of your
applications. All of our GREEN-LINE valves carry at two-year warranty and are available for immediate delivery.
See our comprehensive certification link to GL
requirements that these valves must pass to be called GREEN-LINE. Call for price today and compare. One of the Custom Valve GREEN-LINE program initiatives is to counteract costly
downtime required for standard maintenance. Instead of shutting down operations and ordering a replacement, order one through the Custom Valve GREEN-LINE reconditioned inventory.
Call for a price today and compare.
Green-Line Certified Valve Specifications -
All CVR Green-Line valves shall be processed as follows;
1. Inspection
All CVR Green-Line valves shall be inspected by trained CVR Green-Line technicians.
1-1. Mechanical Integrity
All mechanical parts shall be checked for proper tolerances and integrity of operation.
1-2. Soft Parts and Elastomers
All soft parts shall be inspected and replaced with new if required.
2. Assembly and Testing
CVR Green-Line valves shall be assembled and tested by trained Green-Line technicians. Three tests shall be performed on each valve.
2-1. Shell Test
Shell pressure test shall be performed on each valve to insure body assembly integrity. Shell test will be performed to applicable ANSI shell test specifications.
2-2. Assembly Operational Test
Valve assemblies shall be stroke tested to insure proper operation of the valve and operation if the valve and operator assembly. Assemblies are to be stroked through the complete
operating range multiple times to insure proper operation of the assembly.
2-3. Seat Leak Test
Valve shall be leak tested using applicable ANSI, MSS or other test procedure. Leakage shall be less than manufacturers’ specified leakage.
3. Tagging
Valve shall be tagged with CVR Green-Line certified tag for identification and traceability.
4. Packaging
Valve shall be packaged properly to protect the CVR Green-Line certified valve during shipping and handling to maintain valve condition and operating integrity of the valve when
installed in the process.
5. Warranty
All CVR Green-Line valves shall carry a two-year warranty.